 H HiTRON
2008/04/14
HARMONIC CORRECTION (PFC) AC/DC MEDICAL APPLICATION EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 100 WATTS GREEN POWER SWITCHING POWER SUPPLIES HEMP100G SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT DESKTOP IEC320-3PL/2P AC RECEPTACLE GREEN POWER DESIGN/MEET ENERGY STAR(CEC) LVEVL IV. MEET MEDICAL STANDARDS EN60601-1/UL60601-1 EMI MEET EN55011/FCC CLASS B
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical. Power Factor Correction (PFC) installed. Input Connector: IEC320-3PL/2P AC receptacle. Input Frequency: 50/60Hz. Inrush Current: 7.2Arms @230Vac 50Hz. Input Current: 0.976A@115Vac/0.496A@230Vac Dielectric Withstand: Meet IEC60601-1. EMI: Meet EN55011/FCC Class B. Hold-up Time: 22mS @115Vac/ 43mS@230Vac typical. Green Power: 0.37W @ 132Vac/ 0.50W @264Vac. Earth Leakage: Less than 0.126mA.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: 100 Watts. Output Connector: Optional. Line Regulation: 0.3 % typical. Load Regulation: 2 % typical. Tolerance: 4%. Noise & Ripple: 1% typical peak to peak. OVP: Built-in. (Latch) Adjustability: Not available. Over Temp. Protection (OTP): Installed. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 110-135% rating output wattage. Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 88-90% typical. Switching Frequency: 40-65 KHz. Circuit Topology: Fixed Flyback Circuit. Transient Response: Output voltage returns in less than 1mS following a 25% load change. Safety Standard: Meet Medical standards UL60601-1 / EN60601-1Class I or II. Harmonic Current Emission, EN61000-3-2 compliance. Operating Temperature: 0 to +25/35/40C without derating. (various with output voltage) Storage Temperature: -20 to +85C. Temperature Coefficient: 0.04%/C typical. Cooling: Free air convection. Construction: Impact resistant plastic enclosure case. Power Density: 4.56-5.5 Watts/Cubic inch. Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25C unless otherwise specified. (2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (%). (3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m)cord AWG#18 wires. (4) Due to requests in market and advances in technology, specifications subject to change without notice.
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO. HEMP100G-S120650-7L HEMP100G-S120650-8 HEMP100G-S150620-7L HEMP100G-S150620-8 HEMP100G-S190530-7L HEMP100G-S190530-8 HEMP100G-S240420-7L HEMP100G-S240420-8 HEMP100G-S360270-7L HEMP100G-S360270-8 HEMP100G-S480200-7L HEMP100G-S480200-8 HEMP100G-S580170-7L HEMP100G-S580170-8 AC PLUG DT7L DT8 DT7L DT8 DT7L DT8 DT7L DT8 DT7L DT8 DT7L DT8 DT7L DT8 O/P VOLTAGE 12Vdc 12Vdc 15Vdc 15Vdc 19Vdc 19Vdc 24Vdc 24Vdc 36Vdc 36Vdc 48Vdc 48Vdc 58Vdc 58Vdc O/P CURRENT 6.5A 6.5A 6.2A 6.2A 5.3A 5.3A 4.2A 4.2A 2.7A 2.7A 2.0A 2.0A 1.7A 1.7A
2008/04/14
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 400.0g (14.18 Oz.)


▲Up To Search▲   

 
Price & Availability of HEMP100G-S120650-7L

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X